Chloride penetration in circular concrete columns

Mariantonietta Morga, G.C. Marano

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

Abstract

Most of the diffusion models of chloride ions in reinforced concrete (RC) elements proposed in literature are related to an isotropic homogeneous semi-infinite medium. This assumption reduces the mathematical complexity, but it is correct only for plane RC elements. This work proposes a comparison between the diffusion model of chloride ions in RC circular columns and in RC slab elements. The durability of RC cylindric elements estimated with the circular model instead of the plane model is shown to be shorter. Finally, a guideline is formulated to properly use the standard and more simple plane model instead of the circular one to estimate the time to corrosion initiation of cylindrical RC elements.
OriginalspracheEnglisch
Seiten (von - bis)173-183
Seitenumfang11
FachzeitschriftInternational Journal of Concrete Structures and Materials
PublikationsstatusVeröffentlicht - 2015

Research Field

  • Ehemaliges Research Field - Mobility Systems

Schlagwörter

  • chloride ions diffusion
  • circular column
  • time to corrosion initiation
  • pitting corrosion of rebars

Fingerprint

Untersuchen Sie die Forschungsthemen von „Chloride penetration in circular concrete columns“. Zusammen bilden sie einen einzigartigen Fingerprint.

Diese Publikation zitieren