Abstract
From the rating plate data of an induction motor the nominal efficiency can be determined. Without detailed knowledge of equivalent circuit parameters, partial load behavior cannot be computed. Therefore, a combined calculation and estimation scheme is presented, where the consistent parameters of an equivalent circuit are elaborated, exactly matching the nominal operating point. From these parameters part load efficiencies can be determined.
Originalsprache | Englisch |
---|---|
Titel | Lecture Notes in Eletrical Engineering, Vol. 60 |
Herausgeber (Verlag) | Springer |
Seiten | 71-80 |
Seitenumfang | 10 |
Publikationsstatus | Veröffentlicht - 2010 |
Research Field
- Nicht definiert
Schlagwörter
- Induction motor - consistent parameters - partial load efficiency