Abstract
Hydrogen blending into natural gas grids can support early renewable hydrogen deployment, but admissible injection depends on local gas flow, blending limits, and upstreamv hydrogen concentrations. This paper analyses these effects for a regional high-pressure gas-grid section in Styria, Austria, with two hydrogen injection points. A transient gasnetwork model derives time- and location-dependent injection limits, which are integrated into an electrolyser dispatch optimisation with fixed trailer demand and annual gas-grid injection demand. Three cases are compared: unrestricted injection, a “CH4-based” limit
without upstream hydrogen, and an “H2-aware” case representing potential upstream hydrogen injection. For the analysed configuration, blending constraints shift operation away from favourable electricity-price periods, particularly when low prices coincide with
reduced gas demand.
without upstream hydrogen, and an “H2-aware” case representing potential upstream hydrogen injection. For the analysed configuration, blending constraints shift operation away from favourable electricity-price periods, particularly when low prices coincide with
reduced gas demand.
| Originalsprache | Englisch |
|---|---|
| Seitenumfang | 24 |
| Fachzeitschrift | MDPI Hydrogen Special Issue Green and Low-Emission Hydrogen: Pathways to a Sustainable Future |
| Volume | 7 |
| Issue | 3 |
| DOIs | |
| Publikationsstatus | Veröffentlicht - 31 Juli 2026 |
UN SDGs
Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung
-
SDG 7 – Erschwingliche und saubere Energie
Research Field
- Energy Scenarios & System Planning