Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Impact of Hydrogen-Blending Constraints on Electrolyser Operation and Hydrogen Production Costs: A Case Study of a Regional Gas-Grid Section in Austria

Publikation: Beitrag in Fachzeitschrift › Artikel › Begutachtung

Abstract

Hydrogen blending into natural gas grids can support early renewable hydrogen deployment, but admissible injection depends on local gas flow, blending limits, and upstreamv hydrogen concentrations. This paper analyses these effects for a regional high-pressure gas-grid section in Styria, Austria, with two hydrogen injection points. A transient gasnetwork model derives time- and location-dependent injection limits, which are integrated into an electrolyser dispatch optimisation with fixed trailer demand and annual gas-grid injection demand. Three cases are compared: unrestricted injection, a “CH4-based” limit
without upstream hydrogen, and an “H2-aware” case representing potential upstream hydrogen injection. For the analysed configuration, blending constraints shift operation away from favourable electricity-price periods, particularly when low prices coincide with
reduced gas demand.
OriginalspracheEnglisch
Seitenumfang24
FachzeitschriftMDPI Hydrogen Special Issue Green and Low-Emission Hydrogen: Pathways to a Sustainable Future
Volume7
Issue3
DOIs
PublikationsstatusVeröffentlicht - 31 Juli 2026

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 7 – Erschwingliche und saubere Energie
    SDG 7 – Erschwingliche und saubere Energie

Research Field

  • Energy Scenarios & System Planning

Fingerprint

Untersuchen Sie die Forschungsthemen von „Impact of Hydrogen-Blending Constraints on Electrolyser Operation and Hydrogen Production Costs: A Case Study of a Regional Gas-Grid Section in Austria“. Zusammen bilden sie einen einzigartigen Fingerprint.

Diese Publikation zitieren