Abstract
The majority of industrial controlled induction machine
drives are connected to the mains via a diode bridge. However, if reduction of harmonic currents and / or regenerative operation is desired, replacing the diode bridge by an active front-end (AFE) is
required. This paper describes two models of an AFE: a power balance model disregarding switching effects,and an ideal switching model of a pulse width modulation (PWM) converter. Both models are controlled
utilizing space phasors in a voltage oriented reference frame. Voltage oriented control (VOC) of the mains converter can be compared with field oriented control (FOC) of a machine converter. Design and parametrization of the main parts-synchronization
with mains voltage, current controller and DC voltage controller-are described in detail. Additionally,simulation results proving the implementation and demonstrating possible investigations as well as an outlook on further enhancements are presented.
| Originalsprache | Englisch |
|---|---|
| Titel | www.modelica.org |
| Seitenumfang | 10 |
| Publikationsstatus | Veröffentlicht - 2011 |
| Veranstaltung | 8th International Modelica Conference, Dresden, Germany - Dauer: 20 März 2011 → 22 März 2011 |
Konferenz
| Konferenz | 8th International Modelica Conference, Dresden, Germany |
|---|---|
| Zeitraum | 20/03/11 → 22/03/11 |
Research Field
- Nicht definiert
Schlagwörter
- Active Front-End
- PWM Converter
- Voltage-Oriented Control
Fingerprint
Untersuchen Sie die Forschungsthemen von „Modeling a Mains connected PWM Converter with Voltage-Oriented Control“. Zusammen bilden sie einen einzigartigen Fingerprint.Diese Publikation zitieren
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver