Abstract
A further-developed homogeneous non-equilibrium boiling (HNB) model was proposed for CFD simulations of two-phase ejectors.
Key improvements include a novel physically motivated interfacial area concentration (IAC) model and a simplified calibration procedure for the accommodation coefficient, expressed as a correlation with reduced saturation pressure.
Calibration and validation were performed using experimental data for an R744 ejector from the literature.
The results show an overprediction of the key parameter, the motive mass flow rate, by up to 15% in more than 80% of validation cases.
Comparison with an R1233zd(E) ejector confirmed the increasing trend of the accommodation coefficient, but with significantly different absolute values.
Finally, the model was compared with the homogeneous equilibrium model (HEM), and directions for future improvements were outlined.
Key improvements include a novel physically motivated interfacial area concentration (IAC) model and a simplified calibration procedure for the accommodation coefficient, expressed as a correlation with reduced saturation pressure.
Calibration and validation were performed using experimental data for an R744 ejector from the literature.
The results show an overprediction of the key parameter, the motive mass flow rate, by up to 15% in more than 80% of validation cases.
Comparison with an R1233zd(E) ejector confirmed the increasing trend of the accommodation coefficient, but with significantly different absolute values.
Finally, the model was compared with the homogeneous equilibrium model (HEM), and directions for future improvements were outlined.
| Originalsprache | Englisch |
|---|---|
| Qualifikation | Master of Science |
| Gradverleihende Hochschule |
|
| Betreuer/-in / Berater/-in |
|
| Datum der Bewilligung | 16 Juni 2026 |
| Publikationsstatus | Veröffentlicht - 16 Juni 2026 |
Research Field
- Efficiency in Industrial Processes and Systems
Fingerprint
Untersuchen Sie die Forschungsthemen von „Numerical Simulation of a Supersonic Multiphase Ejector for High-Temperature Heat Pumps“. Zusammen bilden sie einen einzigartigen Fingerprint.Diese Publikation zitieren
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver