Strategies for passivating microneedle-based sensors: development, characterization and comparison

  • Andrea Bocchino
  • , Sofia Rodrigues Teixeira
  • , Fiona Barry
  • , Chinmay Thatte
  • , Adam Ryan
  • , Fahima Rahman
  • , Yuan Hu
  • , Simone Iadanza
  • , Paul Galvin
  • , Steffen Kurzhals
  • , Eva Melnik
  • , Giorgio C. Mutinati
  • , Conor O'Mahony

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

Abstract

Microneedles (MNs) are sharp, pillar-like structures shorter than 1 mm. They can painlessly pierce the stratum corneum (SC), the outermost layer of the skin, and interface with the underlying dermal interstitial fluid, rich in biomarkers. Due to these properties, MNs have been widely investigated for several diagnostic applications. In particular, MN-based biosensors could enable the development of the new generation of minimally invasive continuous monitoring systems. To become a biosensor, the body or the tip of the needles must be functionalized. In addition, the area surrounding the MNs is usually passivated to prevent substrate interferences. Although passivation layers are widely used, there is a lack of characterization of such layers. This work aims at filling this gap, by developing, characterizing, and comparing six different passivation techniques. These include the application of polymethyl methacrylate (PMMA), Epotek 353ND, silicon oxide (SiO2), parylene, varnish and an adhesive film to microneedle arrays. The performance of each method was then assessed using electrochemical measurements, optical and SEM imaging, and contact angle analysis. Significant variability was observed across the various methods and materials. When assessed in terms of the electrochemically active area available after passivation, the tape and parylene were the most promising layers, while varnish and epoxy were the worst performing materials. The PMMA performed better than the other liquid passivations, but still requires refinement due to the high degree of unwanted coverage of the needles. Finally, the SiO2 layer seemed to be a viable option, but also remains in need of additional optimization.
OriginalspracheEnglisch
Aufsatznummer100328
Seitenumfang13
FachzeitschriftSensors and Actuators Reports
Volume9
DOIs
PublikationsstatusVeröffentlicht - 19 Apr. 2025

Research Field

  • Molecular Diagnostics

Fingerprint

Untersuchen Sie die Forschungsthemen von „Strategies for passivating microneedle-based sensors: development, characterization and comparison“. Zusammen bilden sie einen einzigartigen Fingerprint.

Diese Publikation zitieren