Accurate identification of EEG recordings with interictal epileptiform discharges using a hybrid approach: Artificial intelligence supervised by human experts

Mustafa Aykut Kural, Jin Jing, Franz Fürbass, Hannes Perko, Erisela Qerama, Birger Johnsen, Steffen Fuchs, M. Brandon Westover, Sándor Beniczky

Research output: Contribution to journalArticlepeer-review

Abstract

Objective: To evaluate the diagnostic performance of artificial intelligence (AI)– based algorithms for identifying the presence of interictal epileptiform discharges (IEDs) in routine (20- min) electroencephalography (EEG) recordings.Methods: We evaluated two approaches: a fully automated one and a hybrid ap-proach, where three human raters applied an operational IED definition to assess the automated detections grouped into clusters by the algorithms. We used three previously developed AI algorithms: Encevis, SpikeNet, and Persyst. The diag-nostic gold standard (epilepsy or not) was derived from video- EEG recordings of patients' habitual clinical episodes. We compared the algorithms with the gold standard at the recording level (epileptic or not). The independent validation data set (not used for training) consisted of 20- min EEG recordings containing sharp transients (epileptiform or not) from 60 patients: 30 with epilepsy (with a total of 340 IEDs) and 30 with nonepileptic paroxysmal events. We compared sensitivity, specificity, overall accuracy, and the review time- burden of the fully automated and hybrid approaches, with the conventional visual assessment of the whole recordings, based solely on unrestricted expert opinion.Results: For all three AI algorithms, the specificity of the fully automated ap-proach was too low for clinical implementation (16.67%; 63.33%; 3.33%), despite the high sensitivity (96.67%; 66.67%; 100.00%). Using the hybrid approach sig-nificantly increased the specificity (93.33%; 96.67%; 96.67%) with good sensitivity (93.33%; 56.67%; 76.67%). The overall accuracy of the hybrid methods (93.33%; 76.67%; 86.67%) was similar to the conventional visual assessment of the whole recordings (83.33%; 95% confidence interval [CI]: 71.48– 91.70%; p > .5), yet the time- burden of review was significantly lower (p < .001).Significance: The hybrid approach, where human raters apply the operational IED criteria to automated detections of AI- based algorithms, has high specificity, good sensitivity, and overall accuracy similar to conventional EEG reading, with a significantly lower time- burden. The hybrid approach is accurate and suitable for clinical implementation.
Original languageEnglish
Pages (from-to)1064-1073
Number of pages10
JournalEpilepsia
Issue number5
DOIs
Publication statusPublished - 2022

Research Field

  • Medical Signal Analysis

Keywords

  • artificial intelligence
  • automated detection
  • convolutional neural networks
  • deep learning
  • hybrid method
  • interictal epileptiform EEG discharges

Fingerprint