Abstract
From the rating plate data of an induction motor
the nominal efficiency can be determined. Without detailed
knowledge of equivalent circuit parameters, partial load behavior
cannot be computed. Therefore, a combined calculation and
estimation scheme is presented, where the consistent parameters
of an equivalent circuit are elaborated, exactly matching the
nominal operating point. From these parameters part load
efficiencies can be determined.
Original language | English |
---|---|
Title of host publication | Lecture Notes in Engineering and Computer Sciences |
Number of pages | 10 |
Publication status | Published - 2009 |
Event | World Congress of Engineering (WCE 2009) - Duration: 1 Jul 2009 → 3 Jul 2009 |
Conference
Conference | World Congress of Engineering (WCE 2009) |
---|---|
Period | 1/07/09 → 3/07/09 |
Research Field
- Former Research Field - Low Emission Transport
Keywords
- Induction motor
- consistent parameters
- partial