Skip to main navigation Skip to search Skip to main content

"Every breath you take": evaluating sound levels and acoustic characteristics of various neonatal respiratory support and ventilation modalities

  • Sophie Stummer
  • , Christoph Reuter
  • , Isabella Czedik-Eysenberg
  • , Matthias Bertsch
  • , Katrin Klebermass-Schrehof
  • , Johannes Mader
  • , Julia Buchmayer
  • , Lisa Bartha-Doering
  • , Angelika Berger
  • , Vito Giordano
  • Department of Pediatrics and Adolescent, Medicine Comprehensive Center for Pediatrics, Medical University of Vienna
  • University of Vienna
  • University of Music and Performing Arts, Vienna
  • Division of Neonatology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz

Research output: Contribution to journal › Article › peer-review

Abstract

BACKGROUND: Early sensory experiences have a significant impact on the later life of preterm infants. The NICU soundscape is profoundly influenced by various modalities of respiratory support or ventilation, which are often mandatory early in the care. The incubator, believed to shield from external noise, is less effective against noise originating inside. The objective of this study was to evaluate the sound levels and characteristics of frequently used respiratory support and ventilation modalities, taking into consideration the developing auditory system of premature infants.

METHODS: To evaluate sound dynamics inside and outside an incubator during respiratory support/ventilation, experimental recordings were conducted at the Center for Pediatric Simulation Training of the Medical University Vienna. The ventilator used was a FABIAN HFOI®.

RESULTS: Jet CPAP (Continuous positive airway pressure), whether administered via mask or prongs, generates significantly higher sound levels compared to High-flow nasal cannula (HFNC) and to High-frequency oscillatory ventilation (HFOV) delivered through an endotracheal tube. Upon evaluating the sound spectrum of jet CPAP support, a spectral peak is observed within the frequency range of 4 to 8 kHz. Notably, this frequency band aligns with the range where the hearing threshold of preterm infants is at its most sensitive.

CONCLUSION: Non-invasive HFNC and invasive HFOV generate lower sound levels compared to those produced by jet CPAP systems delivered via masks or prongs. Moreover, HFNC and HFOV show a reduced acoustic presence within the frequency range where the preterm infant's hearing is highly sensitive. Therefore, it is reasonable to speculate that the potential for auditory impairment might be more pronounced in preterm infants who require prolonged use of jet CPAP therapy during their time in the incubator.

Original languageEnglish
Article number1379249
Number of pages12
JournalFrontiers in Pediatrics
Volume12
DOIs
Publication statusPublished - 19 Apr 2024

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Research Field

  • Medical Signal Analysis

Keywords

  • Cpap
  • Hfnc
  • Hfov
  • Nicu
  • Noise
  • Preterm infants

Fingerprint

Dive into the research topics of '"Every breath you take": evaluating sound levels and acoustic characteristics of various neonatal respiratory support and ventilation modalities'. Together they form a unique fingerprint.

Cite this