Ultrafiltration-induced decrease in relative blood volume is larger in hemodialysis patients with low specific blood volume: Results from a dialysate bolus administration study

Michael Schmiedecker, Simon Krenn, Maximilian Waller, Christopher Paschen, Sebastian Mussnig, Janosch Niknam, Peter Wabel, Christopher C Mayer, Manfred Hecking, Daniel Schneditz

Research output: Contribution to journalArticlepeer-review

Abstract

INTRODUCTION: Prescribing the ultrafiltration in hemodialysis patients remains challenging and might benefit from the information on absolute blood volume, estimated by intradialytic dialysate bolus administration. Here, we aimed at determining the relationship between absolute blood volume, normalized for body mass (specific blood volume, Vs), and ultrafiltration-induced decrease in relative blood volume (∆RBV) as well as clinical parameters including body mass index (BMI).

METHODS: This retrospective analysis comprised 77 patients who had their dialysate bolus-based absolute blood volume extracted routinely with an automated method. Patient-specific characteristics and ∆RBV were analyzed as a function of Vs, dichotomizing the data above or below a previously proposed threshold of 65 ml/kg for Vs. Statistical methodology comprised descriptive analyses, two-group comparisons, and correlation analyses.

FINDINGS: Median Vs was 68.6 ml/kg (54.9 ml/kg [Quartile 1], 83.4 ml/kg [Quartile 3]). Relative blood volume decreased by 6.3% (2.6%, 12.2%) over the entire hemodialysis session. Vs correlated inversely with BMI (rs = -0.688, p < 0.001). ∆RBV was 9.8% in the group of patients with Vs <65 ml/kg versus 6.0% in the group of patients with Vs ≥65 ml/kg (p = 0.024). The two groups did not differ significantly regarding their specific ultrafiltration volume, normalized for body mass, which amounted to 34.1 ml/kg and 36.0 ml/kg in both groups, respectively (p = 0.630). ∆RBV correlated inversely with Vs (rs = -0.299, p = 0.008).

DISCUSSION: The present study suggests that patients with higher BMI and lower Vs experience larger blood volume changes, despite similar ultrafiltration requirements. These results underline the clinical plausibility and importance of dialysate bolus-based absolute blood volume determination in the assessment of target weight, especially in view of a previous study where intradialytic morbid events could be decreased when the target weight was adjusted, based on Vs.

Original languageEnglish
Pages (from-to)174-183
Number of pages10
JournalHemodialysis International
Volume27
Issue number2
Early online date26 Jan 2023
DOIs
Publication statusPublished - Apr 2023

Research Field

  • Medical Signal Analysis

Keywords

  • blood volume
  • chronic
  • chronic kidney disease
  • fluid status
  • hemodialysis
  • renal dialysis
  • renal insufficiency

Web of Science subject categories (JCR Impact Factors)

  • Urology & Nephrology

Fingerprint

Dive into the research topics of 'Ultrafiltration-induced decrease in relative blood volume is larger in hemodialysis patients with low specific blood volume: Results from a dialysate bolus administration study'. Together they form a unique fingerprint.

Cite this