Abstract

Strengthening using Prestressed Near Surface Mounted Strips Exernally bonded carbon fiber reinforced plastic (CFRP) strips are used since several years for strengthening of structures. The
high strength of the strips cannot be exploited in most applica-tions. Near surface mounted strips offer several advantages, which allow for further optimization together with prestressing. For the prestressing action a special anchoring device, based on the Composite Wedge Principle, was developed, which allows a simple and quick prestressing procedure. Additionally the an-chorage weighs only 8 kg, which is especially beneficial when manipulations on the lower surface of the structure are neces-sary. The anchorage will be removed after prestressing and the permanent anchorage of the ends of the strips will be estab-
lished by bond. No steel parts remain in the structure, after com-pleting the strengthening. This results in low maintenance and a high durability. The efficiency of the developed systems and the prestressed plate strips was examined experimentally. In these investigations a perfect functionality could be demonstrated.
Original languageEnglish
Article number1
Pages (from-to)10
Number of pages18
JournalBeton- und Stahlbetonbau
Volume105
Issue numberHeft 1
DOIs
Publication statusPublished - 2010

Research Field

  • Reliable and Silent Transport Infrastructure